How a Radon Mitigation System Works

Quick Answer: A radon mitigation system works by changing the air pressure under your house. A fan pulls soil gas from beneath the foundation through a sealed PVC pipe and exhausts it above the roof, so radon never gets the chance to enter the living space. This is called active soil depressurization, and a properly installed system typically cuts indoor radon by 80 to 99 percent.

I’ve had radon crews in more basements than I can count, and the system they leave behind looks simple. A pipe, a fan, a little gauge. But the reason it works has less to do with the parts and more to do with what’s happening under the slab. Once you understand that, the rest makes sense. If you want to see what that looks like on a York rowhome or stone foundation, the York radon mitigation page walks through it. If you want measured results, our look at whether radon mitigation works pulls before and after numbers for 9,063 York and Adams homes from PA DEP’s records.

The house is pulling. The system pulls harder.

Radon is a soil gas. It’s under every house in York County, and it doesn’t push its way in. It gets pulled.

Warm air rises and leaks out the top of a house. Something has to replace it, and the easiest source is the ground, through slab cracks, the gap where the floor meets the wall, the sump pit, and every pipe and wire penetration. Builders call this the stack effect. In winter, with the furnace running and the ground frozen, it’s at its strongest. The basement runs at slightly lower pressure than the soil, and soil gas flows toward lower pressure.

A mitigation system flips that. It creates a zone of even lower pressure under the slab, so the soil gas flows toward the pipe instead of toward your basement. That’s the whole idea. You’re not filtering the air and you’re not blocking the gas. You’re giving it a better exit.

The parts, from the ground up

The suction point. The installer cores a hole through the slab, usually 4 to 5 inches across, and digs out a small pit underneath, a cubic foot or so of gravel and dirt. That pit is where the vacuum starts. If the gravel layer under the slab is good, one pit can pull air from under the whole footprint. In tight clay, which we have plenty of around here, the crew may dig a larger pit or add a second suction point. Diagnostic testing on the day of install tells them which.

The pipe. Schedule 40 PVC, 3 or 4 inch, glued at every joint so it’s airtight, and pitched so that condensation drains back down into the pit rather than pooling. The standard calls for at least 1/8 inch of drop per foot on horizontal runs. That pitch is the difference between a system that runs for years and one that gurgles, ices up, and drips on your drywall. The pipe is also supposed to be labeled so nobody cuts into it during a future remodel.

The fan. A sealed inline centrifugal fan, typically 40 to 90 watts, running 24 hours a day. This is the only moving part. Where it goes matters more than most homeowners realize. The pipe below the fan is under suction, so a leak there just pulls in a little basement air. The pipe above the fan is under pressure, and a leak there pushes concentrated soil gas into whatever room it’s in. That’s why the standard says the fan cannot be installed in or below livable space. Attic, garage, or outside on the wall. Never in the basement.

The exhaust. The pipe terminates above the roof. Under the ANSI/AARST standard Pennsylvania uses, the discharge has to be at least a foot above the roof surface, at least 10 feet above the ground, and at least 10 feet from any window, door, or air intake that sits less than 2 feet below it. The point is to keep the gas from being pulled right back in through a bedroom window. There are narrow exceptions for very tall roofs, but if you see an exhaust pipe stopping at the eave next to a second-floor window, ask why.

The manometer. A clear U-shaped tube with colored fluid, mounted on the suction side of the pipe in the basement. When the fan is pulling, the fluid sits at two different heights. When it’s level, the fan has stopped. It measures suction, not radon. A reading of zero doesn’t mean zero radon. It means the system is dead.

The sealing. A good crew seals the sump pit with a gasketed lid, caulks the slab-to-wall joint where it’s accessible, and closes major cracks. This isn’t what lowers the radon. It’s what keeps the fan from wasting suction on basement air instead of soil gas. The EPA is blunt about this: sealing alone has never been shown to lower radon reliably, and it isn’t recommended as a fix by itself. Gas moves through hidden cracks and porous block no matter how much caulk you use on the visible ones.

The electrical. A dedicated switch or disconnect near the fan, in a weatherproof box if it’s outside. Extension cords and attic plug-ins are how fans end up wired into circuits they shouldn’t be on.

Variations for different foundations

The basic version above is sub-slab depressurization on a poured basement floor, and it covers most York County homes. The same principle gets adapted when the house is different.

  • Sump suction. If the house has a sump pit that connects to drain tile around the footer, the crew can seal the lid and pull from the pit itself. The tile loop becomes the collection network.
  • Drain tile suction. Same idea, connected directly to the perimeter drain instead of the sump.
  • Block wall suction. Hollow block foundations, common in older York and Hanover homes, act like a chimney for soil gas. The system pulls from inside the block cavities as well as under the slab.
  • Sub-membrane depressurization. For a dirt crawlspace, a heavy plastic membrane gets sealed over the ground and the pipe pulls from underneath it.
  • Multiple suction points. Additions, split levels, and houses with slabs poured at different times often need more than one pit, because the gravel under one section doesn’t connect to the gravel under the next.

What a passive system is, by contrast

A lot of newer homes have the pipe but no fan. That’s a passive system, and it depends on warm air drifting up the pipe on its own. Sometimes it takes the edge off. Often it doesn’t get a Pennsylvania basement under 4 pCi/L, especially in winter. Adding the fan turns it into an active system, and that conversion is usually the cheapest mitigation job there is. There’s a separate post on this site about builder’s radon pipes if that’s your situation.

How you know it worked

The install isn’t the finish line. The test is.

PA DEP’s guidance says the post-mitigation test should be run no sooner than 24 hours after the fan is turned on, under closed-house conditions. The goal is a reading below 4 pCi/L, and most properly designed systems land well under that. Get the result in writing. A certified mitigator should also leave the system labeled, walk you through the manometer, and hand you a warranty. Fans typically carry a 5-year manufacturer warranty and usually run past it.

After that, the maintenance is almost nothing. Glance at the manometer once a month. Listen for a change in the fan’s hum. And retest every two years, which is what the EPA recommends, or sooner if you finish the basement, replace the HVAC, or do anything else that changes how the house breathes.

What this costs in York County

A standard sub-slab system on a normal poured basement generally runs $800 to $1,200, PA DEP’s figure for most installs. Stone foundations, finished basements, and tight limestone ground that needs multiple suction points push it to $2,500 and up. Whoever does it needs a current PA DEP certification, and you can check that in about five minutes using the state’s directory.

Ask any company you call for its number and check it there. If your test came back high, York PA Radon Pros can get a quote moving.