Does Radon Mitigation Work? What 9,063 York and Adams County Homes Measured Afterward
Quick answer: Yes, and Pennsylvania’s own records show how well. In PA DEP’s mitigation register, 9,063 York and Adams County homes that started at 4.0 pCi/L or higher went from a median of 12.5 pCi/L before the system to 1 pCi/L after, and 98.2% tested under the 4.0 action level on the follow-up test. Statewide, about 97% of 170,077 mitigated Pennsylvania homes passed that first test. The EPA says systems cut radon by 50% to 99%; in the York and Adams records, the median drop was 92%. Homes that started very high ended up in about the same place as homes that started just over the line. What nobody tracks is how those systems hold up years later, so plan on retesting.
KEY TAKEAWAYS
- → 9,063 York and Adams County homes in PA DEP's register with a matched before and after test on the same floor, 1988 to 2026. (PA DEP mitigation register, 2026)
- → 92% Median drop in radon from the pre-mitigation to the post-mitigation test across those homes (12.5 to 1 pCi/L). (PA DEP mitigation register, 2026)
- → 77.0% Share of mitigated York and Adams homes that tested under 2.0 pCi/L afterward, the level EPA says to consider fixing. (PA DEP mitigation register, 2026)
- → 0.9 Median post-mitigation reading (pCi/L) for homes that started at 50 or higher, the same as homes that started between 4 and 8. (PA DEP mitigation register, 2026)
- → 159 York and Adams homes whose recorded post-mitigation test was still at or above 4.0 pCi/L. (PA DEP mitigation register, 2026)
- → 97% Share of 140 randomly selected Minnesota mitigated homes still under 4.0 pCi/L years after install, the closest long-term study. (Steck, Health Physics 103(3), 2012)
- → $1,232 Median system cost recorded in the register for York and Adams installs in 2025, up from $875 in 2015. (PA DEP mitigation register, 2025)
When someone in York County gets a quote for a radon system, the question is always the same: will it actually work, and what number will I end up with? The usual answer is a marketing line about reducing radon by up to 99 percent. Pennsylvania has a better answer sitting in public view. The Department of Environmental Protection keeps a register of mitigation systems with the radon reading taken before each install and the reading taken after, and it publishes that register as open data.
We matched every York and Adams County home in that register where a before test and an after test were taken on the same floor. That gave us 9,063 homes that started at or above the action level. Their median reading fell from 12.5 to 1 pCi/L, and 98.2% tested under 4.0 afterward (PA DEP mitigation register, 2026). The more useful finding is what the number does not depend on, and what nobody in the state is measuring once the installer leaves.
1 Does Radon Mitigation Work in York and Adams County? A 92% Median Drop
Across 9,063 matched York and Adams County homes, mitigation cut the median radon reading by 92%, from 12.5 to 1 pCi/L. York County homes landed under the action level 97.9% of the time and Adams County homes 99.0% of the time, slightly better than Pennsylvania overall at 97.2% (PA DEP mitigation register, 2026).
| METRIC | VALUE | SOURCE |
|---|---|---|
| York County homes matched | 6,802 | PA DEP mitigation register |
| York County: median before (pCi/L) | 13.5 | PA DEP mitigation register |
| York County: median after (pCi/L) | 0.9 | PA DEP mitigation register |
| York County: share under 4.0 after | 97.9% | PA DEP mitigation register |
| Adams County homes matched | 2,261 | PA DEP mitigation register |
| Adams County: median before (pCi/L) | 10.1 | PA DEP mitigation register |
| Adams County: share under 4.0 after | 99.0% | PA DEP mitigation register |
| Pennsylvania homes matched | 170,077 | PA DEP mitigation register |
| Pennsylvania: share under 4.0 after | 97.2% | PA DEP mitigation register |
| Pennsylvania: median reduction | 89.5% | PA DEP mitigation register |
York County homes in the register start higher than Adams County homes. York’s median pre-mitigation reading in the register is 13.5 pCi/L, against 10.1 in Adams County, and still the median York home finished at 0.9. That matters for anyone weighing a reading against the EPA’s risk table: a system does not merely pull a York basement under the line, it typically takes it well below the 2.0 level where the EPA says to consider fixing. Our post on what each radon number means walks through that table.
The share that tested under 2.0, the level where the EPA says to consider fixing, was 77.0%. So roughly three homes in four end up below the stricter line, not just the familiar one. If you want to see where your street starts before a system goes in, the DEP testing averages are broken out in our radon levels by York ZIP code table, and the ZIP results for mitigated homes are in the data explorer below. Hanover’s 17331 shows 98.7% under the action level after mitigation, and Gettysburg’s 17325 shows 99.2%.
2 Does a Higher Starting Number Mean a Worse Result? Homes Starting Near 79 pCi/L Ended at 0.9
No. York and Adams homes that started at 50 pCi/L or higher, with a median of 79, ended at a median of 0.9 pCi/L. Homes that started between 4 and 8, median 5.9, ended at 0.9. The finish line barely moves; only the percentage drop grows, from 83.3% to 98.9% (PA DEP mitigation register, 2026).
| METRIC | VALUE | SOURCE |
|---|---|---|
| Started 4 to 7.9: median before (pCi/L) | 5.9 | PA DEP mitigation register |
| Started 4 to 7.9: median after (pCi/L) | 0.9 | PA DEP mitigation register |
| Started 4 to 7.9: median reduction | 83.3% | PA DEP mitigation register |
| Started 4 to 7.9: share under 2.0 after | 78.9% | PA DEP mitigation register |
| Started 8 to 19.9: median reduction | 91.8% | PA DEP mitigation register |
| Started 20 to 49.9: median reduction | 96.8% | PA DEP mitigation register |
| Started 50 and up: median before (pCi/L) | 79 | PA DEP mitigation register |
| Started 50 and up: median reduction | 98.9% | PA DEP mitigation register |
| Started 50 and up: share under 4.0 after | 95.7% | PA DEP mitigation register |
| Started 50 and up: share under 2.0 after | 76.5% | PA DEP mitigation register |
This is the single most useful number for someone staring at a frightening test result. A reading in the dozens feels like it should need a different kind of fix, and the percentages people quote online make it sound that way: a home that drops by 83.3% sounds worse off than one that drops by 98.9%. In practice both are landing at the same place, under 1 pCi/L. The fan and pipe create a pressure field under the slab, and once that field is established it does not much matter how much radon the soil was pushing up before.
Where the starting number does show up is at the margin. Homes that began at 50 or above passed the action level 95.7% of the time, a few points lower than the bands below them. Those are the houses most likely to need a second suction point or a sealed crawlspace, which is a design question, not a sign the method fails. If your house just tested high, our guide to what happens after a failed radon test covers the order of operations, and buyers in the middle of a sale should read buying a house in York with high radon before treating a big number as a reason to walk.
3 Does the Type of System Matter? Sealing Alone Passed Only 61.5% of the Time
Standard sub-slab systems, the bulk of York and Adams installs at 7,149 homes, put 98.1% under the action level. Activated builder’s pipes put 83.1% under 2.0 pCi/L at a median recorded cost of $650. Sealing cracks without suction was rare and weak: 61.5% under 4.0, median after 3.5 pCi/L (PA DEP mitigation register, 2026).
| METRIC | VALUE | SOURCE |
|---|---|---|
| Standard sub-slab systems (homes) | 7,149 | PA DEP mitigation register |
| Standard sub-slab: share under 4.0 after | 98.1% | PA DEP mitigation register |
| Sub-slab pit cut-out: share under 2.0 after | 82.6% | PA DEP mitigation register |
| Activated passive pipe: share under 2.0 after | 83.1% | PA DEP mitigation register |
| Activated passive pipe: median recorded cost | $650 | PA DEP mitigation register |
| Sealing only: share under 4.0 after | 61.5% | PA DEP mitigation register |
| Sealing only: median after (pCi/L) | 3.5 | PA DEP mitigation register |
The register’s system labels are coarse, but they separate the approaches that matter to a homeowner comparing quotes. Active suction under the slab is what does the work; our explainer on how a radon mitigation system works shows why. Sealing is part of a good install, but on its own it left the median home at 3.5 pCi/L, just under the line, and that is from only thirteen homes, so the exact percentage should not be leaned on.
Newer York County houses often have a passive pipe the builder put in, and activating it with a fan recorded some of the best results in the data at the lowest median cost. The catch is that not every builder’s pipe is connected to anything useful under the slab, which is why our post on activating a builder's radon pipe recommends having a certified mitigator confirm it before you assume the cheap version will work.
4 How Often Does a System Fail Its First Test? 159 of 9,063 York and Adams Homes
Rarely. 159 York and Adams homes, fewer than two in a hundred, had a recorded post-mitigation test still at or above 4.0 pCi/L. Statewide it was 4,683 of 170,077. A widely repeated claim that 5 to 15 percent (commonly cited; no primary source traceable) of installs miss on the first try has no traceable primary source (inspectandtest.net (vendor guide), 2026).
| METRIC | VALUE | SOURCE |
|---|---|---|
| York + Adams homes still at or above 4.0 after | 159 | PA DEP mitigation register |
| Pennsylvania homes still at or above 4.0 after | 4,683 | PA DEP mitigation register |
| Claimed first-try miss rate (vendor, unsourced) | 5 to 15 percent (commonly cited; no primary source traceable) | inspectandtest.net (vendor guide) |
| 1985-87 Pennsylvania EPA demonstration homes still above 4.0 after first installs, of forty | 18 | Brodhead, Measuring At-Grade Radon Mitigation Exhaust (AARST 2020) |
| Homes in PA DEP’s re-entrainment study | Ten homes | PA DEP Bureau of Radiation Protection |
| EPA: reduction some systems achieve | 99 percent | US EPA, Consumer's Guide to Radon Reduction |
A common worry is whether mitigation is reliable, or whether high readings after an install are common. The state data answers the first half clearly. Fewer than two York and Adams homes in a hundred had a recorded post-mitigation result at or above the action level, and the rate statewide was under three in a hundred. It was not always this way. In an EPA demonstration project in eastern Pennsylvania in the mid-1980s, 18 of forty very high homes were still above 4.0 after their first systems (Brodhead, Measuring At-Grade Radon Mitigation Exhaust (AARST 2020), 1987). Venting above the roof is now standard, and a June 2025 PA DEP study of ten homes found that, where exhaust re-entry happened at all, it was not a significant contributor (PA DEP Bureau of Radiation Protection, 2025).
There is a real limit on this number, and it cuts in a specific direction. The register holds what certified contractors report, and a contractor who fixes a failing system before the final test can report the passing one. So the true first-try miss rate is somewhat higher than the register shows, and nobody publishes the call-back rate. That is why the guarantee matters more than the advertised reduction: ask what happens if the post-mitigation test comes back high, and verify the contractor's PA DEP certification before you sign.
5 What Happens After the Install-Day Test? Nobody in Pennsylvania Is Measuring It
Pennsylvania records the test taken right after installation, then stops. DEP’s statewide testing register lists whether a home has a mitigation system as NOT COLLECTED for every York and Adams record (PA DEP Radon Test Results register (data.pa.gov), 2026). The best long-term evidence comes from Minnesota, where 97% of 140 randomly chosen mitigated homes were still under 4.0 years later.
| METRIC | VALUE | SOURCE |
|---|---|---|
| York + Adams test records: system present? | NOT COLLECTED | PA DEP Radon Test Results register (data.pa.gov) |
| Minnesota: mitigated homes still under 4.0 | 97% | Steck, Health Physics 103(3), 2012 |
| Minnesota: homes in the random sample | 140 | Steck, Health Physics 103(3), 2012 |
| Minnesota: share under 2.0 | 90% | Steck, AARST Symposium 2008 |
| Minnesota: average system age | 2.3 years | Steck, AARST Symposium 2008 |
| Minnesota: owners who ran their own follow-up test | 60% | Steck, AARST Symposium 2008 |
| PA DEP retest reminder targets systems installed at least | 2 years ago | PA DEP Radon Division stakeholder update, Sept 2025 |
This is the gap no one in the conversation is filling. Every number above describes the house on the day the system was proven. A radon fan runs around the clock and eventually wears out, pipes get bumped, basements get finished and new cracks open, and none of that shows up in a register built from install-day tests. The Minnesota study is the closest thing to an answer: with systems averaging 2.3 years old, 97% were still under the action level and 90% under 2.0 (Steck, AARST Symposium 2008, 2008). That is reassuring, but it is one state, a modest sample and data collected years ago.
The same study found that only about 60% of owners had ever run their own follow-up test. Pennsylvania’s DEP has begun sending retest reminders for homes whose systems were installed at least 2 years ago (PA DEP Radon Division stakeholder update, Sept 2025, 2025), which tells you the agency sees the same problem. A dead fan is silent, and our post on how long a radon system lasts explains how to read the manometer. A long-term test every two years, or a good continuous monitor, is how you find out before the number creeps back; our comparison of home monitors and professional tests covers which to trust.
6 What Do York-Area Systems Cost Now? A Median of $1,232 in 2025
The median system cost recorded for York and Adams installs rose from $875 in 2015 to $1,232 in 2025, and $1,242 so far in 2026. That sits just above DEP’s current guidance for most systems, which starts at $800 for most systems. Contractors reported 469 local systems in 2025, below the 607 peak (PA DEP mitigation register, 2025).
| METRIC | VALUE | SOURCE |
|---|---|---|
| Median recorded cost, 2015 | $875 | PA DEP mitigation register |
| Median recorded cost, 2025 | $1,232 | PA DEP mitigation register |
| Median recorded cost, 2026 to date | $1,242 | PA DEP mitigation register |
| PA DEP guidance, low end of typical range | $800 | PA DEP Radon Action Month release, Jan 2026 |
| Systems reported, 2025 | 469 | PA DEP mitigation register |
| Systems reported, peak year | 607 | PA DEP mitigation register |
| Register records, York County | 21,258 | PA DEP mitigation register |
These are the prices contractors entered when they reported the job, in the dollars of the year it was done, so they track what York and Adams homeowners actually paid rather than what an online calculator suggests. The rise since 2015 is steady rather than sudden, and the recorded 2025 median sits just above DEP’s typical range. Our York radon mitigation cost guide explains what pushes a single house above or below that median: stone foundations, crawlspaces, a finished basement or a second slab.
Put the two halves of this article together and the decision gets simpler. The result a York County homeowner can expect is not much affected by how bad the reading was, and the price is not much affected either. What varies is the house, and whether anyone checks the system after year one. In the highest-reading parts of the county the pattern holds: Red Lion’s 17356 started at a median of 16.45 pCi/L and finished at 0.7, and our Red Lion radon mitigation page lists the local crews.

Looking for a company? The directory lists the radon mitigation companies in York PA and nearby towns, each of which states that it holds PA DEP certification. If you live in or around the city, start with the companies that serve York. For the countywide list, see certified radon mitigation contractors in York County.
Explore every figure in this article

Methodology
We downloaded nothing by hand: every PA DEP figure on this page comes from a query against DEP’s Radon Mitigation System register on data.pa.gov, refreshed by DEP in October 2026, and each source link opens the exact query that returns it. A home counts when its pre-mitigation test at the primary location read 4.0 pCi/L or higher and DEP’s test identifiers link it to a post-mitigation test on the same floor, which covers both of DEP’s identifier schemes since 1988. Post-mitigation results are short-term tests reported by certified contractors shortly after installation; the register cannot show call-backs, later failures or homes that were never retested, and DEP’s testing register does not record whether a tested home has a system. Percentages are truncated to one decimal, and costs are nominal. Long-term figures come from a Minnesota study, not Pennsylvania. Query responses were checked against the published values directly; PDF sources were checked by extracting their text; the EPA guide, which blocks automated access, was read manually; one vendor figure with no traceable source is labelled as such. Two research steps ran in reduced form: this site’s own page inventory was read from its sitemap and five key pages rather than crawled, because the host blocks automated requests, and the comparison of which content formats earn links in this niche used three named radon sites after automatic competitor discovery returned only vendor link profiles.
- Sources consulted: 31
- Sources cited: 17
- Data freshness: current year: 11, last year: 2, older: 4
- Data range: 1988-01-01 to 2026-10-24
- Research date: 2026-10-24
- Update schedule: Annually, after DEP's first-quarter register refresh
- Limitations: Post-mitigation results are short-term tests reported to DEP by certified contractors shortly after installation; the register cannot show call-backs, later failures or untested homes. Matching pairs a pre-test with a post-test at the same location and floor using DEP's test result identifiers. Percentages are truncated, not rounded, to one decimal. Long-term figures come from Minnesota, not Pennsylvania.
Using this data: You are welcome to use these figures or charts in your own article, report or presentation, with a link back to this page as the source.
Frequently Asked Questions
How much does radon mitigation lower radon levels in York County?
In PA DEP's register, 9,063 mitigated York and Adams County homes went from a median of 12.5 pCi/L before to 1 pCi/L after, a median drop of 92%. 98.2% tested under the 4.0 action level on the post-mitigation test, and 77% tested under 2.0. Results come from contractor-reported short-term tests taken shortly after installation. (PA DEP mitigation register, 2026)
Does a very high radon reading mean mitigation will work less well?
No. In the York and Adams data, homes that started at 50 pCi/L or higher (median 79) ended at a median of 0.9 pCi/L after mitigation, the same as homes that started between 4 and 8. Higher starting homes still landed under 4.0 95.7% of the time. The percentage drop is bigger because the starting number is bigger. (PA DEP mitigation register, 2026)
How often does a radon system fail its first test?
Rarely in the state data. 159 of 9,063 York and Adams homes, fewer than 2 in 100, had a recorded post-mitigation test at or above 4.0 pCi/L, and 4,683 of 170,077 statewide. Vendor guides often claim 5 to 15 percent of installs miss on the first try, but cite no source. The register records what certified contractors report and cannot show call-backs. (PA DEP mitigation register, 2026)
Do radon systems keep working years later?
Pennsylvania does not track it: DEP's test-results register does not record whether a tested home has a system. The best long-term evidence comes from Minnesota, where a peer-reviewed study of 140 randomly selected mitigated homes found about 97% still under the action level years after installation. An earlier report from the same project put the average system age at 2.3 years. DEP recommends retesting every two years. (Steck, Health Physics 103(3), 2012; Steck, AARST Symposium 2008)
What does radon mitigation cost in York County now?
The median system cost recorded in PA DEP's register for York and Adams County installs was $1,232 in 2025, up from $875 in 2015. Activating a builder's passive pipe recorded a median of $650 across all years. DEP's January 2026 guidance still puts most systems at $800 to $1,200, so recent local jobs sit at or slightly above that range. (PA DEP mitigation register, 2025)
Is sealing cracks enough to fix radon?
Not usually. Only 13 York and Adams homes in the register were treated with sealing alone; their median post-mitigation reading was 3.5 pCi/L and just 61.5% tested under 4.0, against 98.1% for standard sub-slab systems across 7,149 homes. The sealing sample is small, but the gap matches EPA guidance that sealing works best as part of a suction system. (PA DEP mitigation register, 2026)
What if radon is still high after mitigation?
It happens, but rarely. 159 of 9,063 York and Adams homes in PA DEP’s register, fewer than 2 in 100, had a follow-up test at or above 4.0 pCi/L. The first call is back to the installer, who can check the fan and suction and may add a suction point, change the fan, or seal a sump or large opening. Check that the fan is running and the manometer shows suction, then retest. Our guide to what happens after a failed radon test covers the next steps.
Is radon mitigation a hoax?
No. The results are measured, not claimed. Of 9,063 York and Adams County homes in PA DEP’s register that started at 4.0 pCi/L or higher, 98.2% tested under 4.0 after a system went in, and the median reading fell from 12.5 to 1 pCi/L. Those follow-up tests are reported by the contractors, so it is reasonable to run your own independent test afterward, which the EPA recommends anyway. For why radon matters, see the EPA’s radon page.
Sources & References
- PA DEP mitigation register. “Matched before/after results, York and Adams counties.” data.pa.gov/resource/vm4e-6nir.json?%24query=SELECT+count%28%2A%29+AS+homes%2C+m. Accessed 2026-10-24.
- PA DEP mitigation register. “Matched before/after results by county.” data.pa.gov/resource/vm4e-6nir.json?%24query=SELECT+mitigationcounty%2C+count%28. Accessed 2026-10-24.
- PA DEP mitigation register. “Matched before/after results, all Pennsylvania.” data.pa.gov/resource/vm4e-6nir.json?%24query=SELECT+count%28%2A%29+AS+homes%2C+m. Accessed 2026-10-24.
- PA DEP mitigation register. “Results by starting radon level, York and Adams.” data.pa.gov/resource/vm4e-6nir.json?%24query=SELECT+case%28measurevalue%3A%3Anum. Accessed 2026-10-24.
- PA DEP mitigation register. “Results by system type, York and Adams.” data.pa.gov/resource/vm4e-6nir.json?%24query=SELECT+remediationsystemdesc%2C+cou. Accessed 2026-10-24.
- PA DEP mitigation register. “Results by ZIP code, York and Adams.” data.pa.gov/resource/vm4e-6nir.json?%24query=SELECT+substring%28addresspostalcod. Accessed 2026-10-24.
- PA DEP mitigation register. “Systems and median cost by year, York and Adams.” data.pa.gov/resource/vm4e-6nir.json?%24query=SELECT+mitiyear%2C+count%28%2A%29+A. Accessed 2026-10-24.
- PA DEP mitigation register. “Register records by county.” data.pa.gov/resource/vm4e-6nir.json?%24query=SELECT+mitigationcounty%2C+count%28. Accessed 2026-10-24.
- PA DEP Radon Test Results register (data.pa.gov). “Mitigation-system field, York and Adams test records.” data.pa.gov/resource/vkjb-sx3k.json?%24query=SELECT+county_name%2C+mitigation_sy. Accessed 2026-10-24.
- Steck, Health Physics 103(3), 2012. “The effectiveness of mitigation for reducing radon risk in single-family Minnesota homes.” digitalcommons.csbsju.edu/physics_pubs/1. Accessed 2026-10-24.
- Steck, AARST Symposium 2008. “Post Mitigation Radon Concentrations in Minnesota Homes.” employees.csbsju.edu/dsteck/mnradon/16-POST-MITIGATION_RADON_CONCENTRATIONS_IN_M. Accessed 2026-10-24.
- PA DEP Radon Division stakeholder update, Sept 2025. “PA Radon Division update, subsequent post-mitigation testing.” sosradon.org/sites/sosradon/files/Stakeholders_Meetings/PA%20STAKEHOLDER_MTG-DIV. Accessed 2026-10-24.
- PA DEP Bureau of Radiation Protection. “Exploratory Study of ASD Ground-Level Exhaust on Radon Re-entrainment.” sosradon.org/sites/sosradon/files/Stakeholders_Meetings/Radon%20Re-entrainment%2. Accessed 2026-10-24.
- Brodhead, Measuring At-Grade Radon Mitigation Exhaust (AARST 2020). “Measuring At-Grade Radon Mitigation Exhaust.” wpb-radon.com/Radon_research_papers/2020%20Virtual%20Conference/Measuring%20at%2. Accessed 2026-10-24.
- US EPA, Consumer's Guide to Radon Reduction. “A Consumer's Guide to Radon Reduction: How to Fix Your Home.” epa.gov/sites/production/files/2016-02/documents/2013_consumers_guide_to_radon_r. Accessed 2026-10-24.
- PA DEP Radon Action Month release, Jan 2026. “DEP Encourages Pennsylvanians to Test Their Homes for Radon.” pa.gov/agencies/dep/newsroom/2026-01-12-dep-encourages-pennsylvanians-to-test-th. Accessed 2026-10-24.
- inspectandtest.net (vendor guide). “Radon elimination system guide.” inspectandtest.net/guides/radon-elimination-system/. Accessed 2026-10-24.
