Watercolor and ink sketch of two gauges, one high in an orange zone and one low in a teal zone, with a white radon pipe behind them, with the title Does Radon Mitigation Work?

Does Radon Mitigation Work? What 9,063 York and Adams County Homes Measured Afterward

Quick answer: Yes, and Pennsylvania’s own records show how well. In PA DEP’s mitigation register, 9,063 York and Adams County homes that started at 4.0 pCi/L or higher went from a median of 12.5 pCi/L before the system to 1 pCi/L after, and 98.2% tested under the 4.0 action level on the follow-up test. Statewide, about 97% of 170,077 mitigated Pennsylvania homes passed that first test. The EPA says systems cut radon by 50% to 99%; in the York and Adams records, the median drop was 92%. Homes that started very high ended up in about the same place as homes that started just over the line. What nobody tracks is how those systems hold up years later, so plan on retesting.

98.2%
Of 9,063 York and Adams County homes that tested at 4.0 pCi/L or higher and were mitigated, 98.2% tested under 4.0 on the post-mitigation test at the same spot, per PA DEP's mitigation register.
Source: PA DEP mitigation register (2026)

KEY TAKEAWAYS

When someone in York County gets a quote for a radon system, the question is always the same: will it actually work, and what number will I end up with? The usual answer is a marketing line about reducing radon by up to 99 percent. Pennsylvania has a better answer sitting in public view. The Department of Environmental Protection keeps a register of mitigation systems with the radon reading taken before each install and the reading taken after, and it publishes that register as open data.

We matched every York and Adams County home in that register where a before test and an after test were taken on the same floor. That gave us 9,063 homes that started at or above the action level. Their median reading fell from 12.5 to 1 pCi/L, and 98.2% tested under 4.0 afterward (PA DEP mitigation register, 2026). The more useful finding is what the number does not depend on, and what nobody in the state is measuring once the installer leaves.

1 Does Radon Mitigation Work in York and Adams County? A 92% Median Drop

Across 9,063 matched York and Adams County homes, mitigation cut the median radon reading by 92%, from 12.5 to 1 pCi/L. York County homes landed under the action level 97.9% of the time and Adams County homes 99.0% of the time, slightly better than Pennsylvania overall at 97.2% (PA DEP mitigation register, 2026).

METRICVALUESOURCE
York County homes matched6,802PA DEP mitigation register
York County: median before (pCi/L)13.5PA DEP mitigation register
York County: median after (pCi/L)0.9PA DEP mitigation register
York County: share under 4.0 after97.9%PA DEP mitigation register
Adams County homes matched2,261PA DEP mitigation register
Adams County: median before (pCi/L)10.1PA DEP mitigation register
Adams County: share under 4.0 after99.0%PA DEP mitigation register
Pennsylvania homes matched170,077PA DEP mitigation register
Pennsylvania: share under 4.0 after97.2%PA DEP mitigation register
Pennsylvania: median reduction89.5%PA DEP mitigation register
49.4%
About half of mitigated York and Adams homes tested under 1 pCi/L on the follow-up test.
PA DEP mitigation register, 2026

York County homes in the register start higher than Adams County homes. York’s median pre-mitigation reading in the register is 13.5 pCi/L, against 10.1 in Adams County, and still the median York home finished at 0.9. That matters for anyone weighing a reading against the EPA’s risk table: a system does not merely pull a York basement under the line, it typically takes it well below the 2.0 level where the EPA says to consider fixing. Our post on what each radon number means walks through that table.

The share that tested under 2.0, the level where the EPA says to consider fixing, was 77.0%. So roughly three homes in four end up below the stricter line, not just the familiar one. If you want to see where your street starts before a system goes in, the DEP testing averages are broken out in our radon levels by York ZIP code table, and the ZIP results for mitigated homes are in the data explorer below. Hanover’s 17331 shows 98.7% under the action level after mitigation, and Gettysburg’s 17325 shows 99.2%.

2 Does a Higher Starting Number Mean a Worse Result? Homes Starting Near 79 pCi/L Ended at 0.9

No. York and Adams homes that started at 50 pCi/L or higher, with a median of 79, ended at a median of 0.9 pCi/L. Homes that started between 4 and 8, median 5.9, ended at 0.9. The finish line barely moves; only the percentage drop grows, from 83.3% to 98.9% (PA DEP mitigation register, 2026).

METRICVALUESOURCE
Started 4 to 7.9: median before (pCi/L)5.9PA DEP mitigation register
Started 4 to 7.9: median after (pCi/L)0.9PA DEP mitigation register
Started 4 to 7.9: median reduction83.3%PA DEP mitigation register
Started 4 to 7.9: share under 2.0 after78.9%PA DEP mitigation register
Started 8 to 19.9: median reduction91.8%PA DEP mitigation register
Started 20 to 49.9: median reduction96.8%PA DEP mitigation register
Started 50 and up: median before (pCi/L)79PA DEP mitigation register
Started 50 and up: median reduction98.9%PA DEP mitigation register
Started 50 and up: share under 4.0 after95.7%PA DEP mitigation register
Started 50 and up: share under 2.0 after76.5%PA DEP mitigation register
76.5%
Even among the worst-starting homes, three in four ended under 2 pCi/L.
PA DEP mitigation register, 2026

Median radon reduction by starting level, York and Adams County

Started at 4 to 7.9
83.3%
Started at 8 to 19.9
91.8%
Started at 20 to 49.9
96.8%
Started at 50 or more
98.9%

This is the single most useful number for someone staring at a frightening test result. A reading in the dozens feels like it should need a different kind of fix, and the percentages people quote online make it sound that way: a home that drops by 83.3% sounds worse off than one that drops by 98.9%. In practice both are landing at the same place, under 1 pCi/L. The fan and pipe create a pressure field under the slab, and once that field is established it does not much matter how much radon the soil was pushing up before.

Where the starting number does show up is at the margin. Homes that began at 50 or above passed the action level 95.7% of the time, a few points lower than the bands below them. Those are the houses most likely to need a second suction point or a sealed crawlspace, which is a design question, not a sign the method fails. If your house just tested high, our guide to what happens after a failed radon test covers the order of operations, and buyers in the middle of a sale should read buying a house in York with high radon before treating a big number as a reason to walk.

3 Does the Type of System Matter? Sealing Alone Passed Only 61.5% of the Time

Standard sub-slab systems, the bulk of York and Adams installs at 7,149 homes, put 98.1% under the action level. Activated builder’s pipes put 83.1% under 2.0 pCi/L at a median recorded cost of $650. Sealing cracks without suction was rare and weak: 61.5% under 4.0, median after 3.5 pCi/L (PA DEP mitigation register, 2026).

METRICVALUESOURCE
Standard sub-slab systems (homes)7,149PA DEP mitigation register
Standard sub-slab: share under 4.0 after98.1%PA DEP mitigation register
Sub-slab pit cut-out: share under 2.0 after82.6%PA DEP mitigation register
Activated passive pipe: share under 2.0 after83.1%PA DEP mitigation register
Activated passive pipe: median recorded cost$650PA DEP mitigation register
Sealing only: share under 4.0 after61.5%PA DEP mitigation register
Sealing only: median after (pCi/L)3.5PA DEP mitigation register
61.5%
Sealing without a fan left nearly four in ten treated homes still above the action level. The sample is small, so read it as a warning, not a rate.
PA DEP mitigation register, 2026

The register’s system labels are coarse, but they separate the approaches that matter to a homeowner comparing quotes. Active suction under the slab is what does the work; our explainer on how a radon mitigation system works shows why. Sealing is part of a good install, but on its own it left the median home at 3.5 pCi/L, just under the line, and that is from only thirteen homes, so the exact percentage should not be leaned on.

Newer York County houses often have a passive pipe the builder put in, and activating it with a fan recorded some of the best results in the data at the lowest median cost. The catch is that not every builder’s pipe is connected to anything useful under the slab, which is why our post on activating a builder's radon pipe recommends having a certified mitigator confirm it before you assume the cheap version will work.

4 How Often Does a System Fail Its First Test? 159 of 9,063 York and Adams Homes

Rarely. 159 York and Adams homes, fewer than two in a hundred, had a recorded post-mitigation test still at or above 4.0 pCi/L. Statewide it was 4,683 of 170,077. A widely repeated claim that 5 to 15 percent (commonly cited; no primary source traceable) of installs miss on the first try has no traceable primary source (inspectandtest.net (vendor guide), 2026).

METRICVALUESOURCE
York + Adams homes still at or above 4.0 after159PA DEP mitigation register
Pennsylvania homes still at or above 4.0 after4,683PA DEP mitigation register
Claimed first-try miss rate (vendor, unsourced)5 to 15 percent (commonly cited; no primary source traceable)inspectandtest.net (vendor guide)
1985-87 Pennsylvania EPA demonstration homes still above 4.0 after first installs, of forty18Brodhead, Measuring At-Grade Radon Mitigation Exhaust (AARST 2020)
Homes in PA DEP’s re-entrainment studyTen homesPA DEP Bureau of Radiation Protection
EPA: reduction some systems achieve99 percentUS EPA, Consumer's Guide to Radon Reduction
18
In the 1980s Pennsylvania demonstration project, nearly half the homes still read above the action level after their first systems. Today’s register shows fewer than two in a hundred.
Brodhead, Measuring At-Grade Radon Mitigation Exhaust (AARST 2020), 1987

A common worry is whether mitigation is reliable, or whether high readings after an install are common. The state data answers the first half clearly. Fewer than two York and Adams homes in a hundred had a recorded post-mitigation result at or above the action level, and the rate statewide was under three in a hundred. It was not always this way. In an EPA demonstration project in eastern Pennsylvania in the mid-1980s, 18 of forty very high homes were still above 4.0 after their first systems (Brodhead, Measuring At-Grade Radon Mitigation Exhaust (AARST 2020), 1987). Venting above the roof is now standard, and a June 2025 PA DEP study of ten homes found that, where exhaust re-entry happened at all, it was not a significant contributor (PA DEP Bureau of Radiation Protection, 2025).

There is a real limit on this number, and it cuts in a specific direction. The register holds what certified contractors report, and a contractor who fixes a failing system before the final test can report the passing one. So the true first-try miss rate is somewhat higher than the register shows, and nobody publishes the call-back rate. That is why the guarantee matters more than the advertised reduction: ask what happens if the post-mitigation test comes back high, and verify the contractor's PA DEP certification before you sign.

5 What Happens After the Install-Day Test? Nobody in Pennsylvania Is Measuring It

Pennsylvania records the test taken right after installation, then stops. DEP’s statewide testing register lists whether a home has a mitigation system as NOT COLLECTED for every York and Adams record (PA DEP Radon Test Results register (data.pa.gov), 2026). The best long-term evidence comes from Minnesota, where 97% of 140 randomly chosen mitigated homes were still under 4.0 years later.

METRICVALUESOURCE
York + Adams test records: system present?NOT COLLECTEDPA DEP Radon Test Results register (data.pa.gov)
Minnesota: mitigated homes still under 4.097%Steck, Health Physics 103(3), 2012
Minnesota: homes in the random sample140Steck, Health Physics 103(3), 2012
Minnesota: share under 2.090%Steck, AARST Symposium 2008
Minnesota: average system age2.3 yearsSteck, AARST Symposium 2008
Minnesota: owners who ran their own follow-up test60%Steck, AARST Symposium 2008
PA DEP retest reminder targets systems installed at least2 years agoPA DEP Radon Division stakeholder update, Sept 2025
60%
In the Minnesota study, about four owners in ten had never tested their own system after the installer’s check.
Steck, AARST Symposium 2008, 2008

This is the gap no one in the conversation is filling. Every number above describes the house on the day the system was proven. A radon fan runs around the clock and eventually wears out, pipes get bumped, basements get finished and new cracks open, and none of that shows up in a register built from install-day tests. The Minnesota study is the closest thing to an answer: with systems averaging 2.3 years old, 97% were still under the action level and 90% under 2.0 (Steck, AARST Symposium 2008, 2008). That is reassuring, but it is one state, a modest sample and data collected years ago.

The same study found that only about 60% of owners had ever run their own follow-up test. Pennsylvania’s DEP has begun sending retest reminders for homes whose systems were installed at least 2 years ago (PA DEP Radon Division stakeholder update, Sept 2025, 2025), which tells you the agency sees the same problem. A dead fan is silent, and our post on how long a radon system lasts explains how to read the manometer. A long-term test every two years, or a good continuous monitor, is how you find out before the number creeps back; our comparison of home monitors and professional tests covers which to trust.

6 What Do York-Area Systems Cost Now? A Median of $1,232 in 2025

The median system cost recorded for York and Adams installs rose from $875 in 2015 to $1,232 in 2025, and $1,242 so far in 2026. That sits just above DEP’s current guidance for most systems, which starts at $800 for most systems. Contractors reported 469 local systems in 2025, below the 607 peak (PA DEP mitigation register, 2025).

METRICVALUESOURCE
Median recorded cost, 2015$875PA DEP mitigation register
Median recorded cost, 2025$1,232PA DEP mitigation register
Median recorded cost, 2026 to date$1,242PA DEP mitigation register
PA DEP guidance, low end of typical range$800PA DEP Radon Action Month release, Jan 2026
Systems reported, 2025469PA DEP mitigation register
Systems reported, peak year607PA DEP mitigation register
Register records, York County21,258PA DEP mitigation register
$1,232
The recorded median for 2025 sits just above the $800 to $1,200 range PA DEP still gives for most systems.
PA DEP mitigation register, 2025

These are the prices contractors entered when they reported the job, in the dollars of the year it was done, so they track what York and Adams homeowners actually paid rather than what an online calculator suggests. The rise since 2015 is steady rather than sudden, and the recorded 2025 median sits just above DEP’s typical range. Our York radon mitigation cost guide explains what pushes a single house above or below that median: stone foundations, crawlspaces, a finished basement or a second slab.

Put the two halves of this article together and the decision gets simpler. The result a York County homeowner can expect is not much affected by how bad the reading was, and the price is not much affected either. What varies is the house, and whether anyone checks the system after year one. In the highest-reading parts of the county the pattern holds: Red Lion’s 17356 started at a median of 16.45 pCi/L and finished at 0.7, and our Red Lion radon mitigation page lists the local crews.

Key statistics on radon levels after mitigation in York and Adams County, PA: 9,063 homes, a 92% median drop from 12.5 to 1 pCi/L, and 77% under 2.0 pCi/L afterward
Key statistics at a glance | Source: see numbered sources below

Looking for a company? The directory lists the radon mitigation companies in York PA and nearby towns, each of which states that it holds PA DEP certification. If you live in or around the city, start with the companies that serve York. For the countywide list, see certified radon mitigation contractors in York County.

Explore every figure in this article

MetricValueYearSource
Started at 4 to 7.983.3%2026PA DEP mitigation register
Started at 8 to 19.991.8%2026PA DEP mitigation register
Started at 20 to 49.996.8%2026PA DEP mitigation register
Started at 50 or more98.9%2026PA DEP mitigation register
York County homes with a matched before/after test6,8022026PA DEP mitigation register
York County: share under 4.0 pCi/L after mitigation97.9%2026PA DEP mitigation register
York County: median reading before13.52026PA DEP mitigation register
York County: median reading after0.92026PA DEP mitigation register
Adams County homes with a matched before/after test2,2612026PA DEP mitigation register
Adams County: share under 4.0 pCi/L after mitigation99.0%2026PA DEP mitigation register
Adams County: median reading before10.12026PA DEP mitigation register
Pennsylvania homes with a matched before/after test170,0772026PA DEP mitigation register
Pennsylvania: share under 4.0 pCi/L after mitigation97.2%2026PA DEP mitigation register
Pennsylvania: median reduction89.5%2026PA DEP mitigation register
York + Adams: share under 1.0 pCi/L after mitigation49.4%2026PA DEP mitigation register
York + Adams: median reading before12.52026PA DEP mitigation register
York + Adams: median reading after12026PA DEP mitigation register
Started 4 to 7.9: median reading after0.92026PA DEP mitigation register
Started 50 and up: median reading before792026PA DEP mitigation register
Started 50 and up: share under 4.0 after95.7%2026PA DEP mitigation register
Started 4 to 7.9: share under 2.0 after78.9%2026PA DEP mitigation register
Started 50 and up: share under 2.0 after76.5%2026PA DEP mitigation register
Started 4 to 7.9: median reading before5.92026PA DEP mitigation register
Standard sub-slab systems (homes)7,1492026PA DEP mitigation register
Standard sub-slab: share under 4.0 after98.1%2026PA DEP mitigation register
Activated builder's passive pipe: share under 2.0 after83.1%2026PA DEP mitigation register
Activated builder's passive pipe: median recorded cost$6502026PA DEP mitigation register
Sealing only (13 homes): share under 4.0 after61.5%2026PA DEP mitigation register
Sealing only: median reading after3.52026PA DEP mitigation register
Sub-slab pit cut-out: share under 2.0 after82.6%2026PA DEP mitigation register
York + Adams homes still at or above 4.0 after install1592026PA DEP mitigation register
Pennsylvania homes still at or above 4.0 after install4,6832026PA DEP mitigation register
1985-87 EPA demonstration homes in Pennsylvania still above 4.0 after first installs (of 40)181987Brodhead, Measuring At-Grade Radon Mitigation Exhaust (AARST 2020)
PA DEP re-entrainment study: homes monitoredTen homes2025PA DEP Bureau of Radiation Protection
Commonly claimed share of installs that miss 4.0 on the first try5 to 15 percent2026inspectandtest.net (vendor guide)
EPA: reduction some systems can achieve99 percent2013US EPA, Consumer's Guide to Radon Reduction
Minnesota study homes still under 4.0 years after mitigation97%2008Steck, Health Physics 103(3), 2012
Minnesota study: randomly selected mitigated homes1402008Steck, Health Physics 103(3), 2012
Minnesota study: share under 2.0 (systems averaging 2.3 years old)90%2008Steck, AARST Symposium 2008
Minnesota study: average system age2.3 years2008Steck, AARST Symposium 2008
Minnesota study: homeowners who ran their own follow-up test60%2008Steck, AARST Symposium 2008
York + Adams residential test records with 'mitigation system present' not collectedNOT COLLECTED2026PA DEP Radon Test Results register (data.pa.gov)
DEP retest reminder targets systems installed at least2 years ago2025PA DEP Radon Division stakeholder update, Sept 2025
Median recorded system cost, York + Adams, 2015$8752015PA DEP mitigation register
Median recorded system cost, York + Adams, 2025$1,2322025PA DEP mitigation register
Systems reported, York + Adams, 20254692025PA DEP mitigation register
Systems reported, York + Adams, 2011 (peak year)6072011PA DEP mitigation register
Median recorded system cost, York + Adams, 2026 to date$1,2422026PA DEP mitigation register
PA DEP: typical system cost range (low end)$8002026PA DEP Radon Action Month release, Jan 2026
Records in the register, York County21,2582026PA DEP mitigation register
Hanover 17331: share under 4.0 after (1,445 homes)98.7%2026PA DEP mitigation register
Gettysburg 17325: share under 4.0 after (771 homes)99.2%2026PA DEP mitigation register
Red Lion 17356: median reading before16.452026PA DEP mitigation register
Red Lion 17356: median reading after0.72026PA DEP mitigation register
York 17403: share under 4.0 after (505 homes)96.8%2026PA DEP mitigation register
York 17402: share under 4.0 after (685 homes)97.8%2026PA DEP mitigation register
Bar chart of median radon reduction after mitigation by starting level in York and Adams County, from 83.3% for homes starting at 4 to 7.9 pCi/L to 98.9% for homes starting at 50 or more
Comparison | Source: see numbered sources below

Methodology

We downloaded nothing by hand: every PA DEP figure on this page comes from a query against DEP’s Radon Mitigation System register on data.pa.gov, refreshed by DEP in October 2026, and each source link opens the exact query that returns it. A home counts when its pre-mitigation test at the primary location read 4.0 pCi/L or higher and DEP’s test identifiers link it to a post-mitigation test on the same floor, which covers both of DEP’s identifier schemes since 1988. Post-mitigation results are short-term tests reported by certified contractors shortly after installation; the register cannot show call-backs, later failures or homes that were never retested, and DEP’s testing register does not record whether a tested home has a system. Percentages are truncated to one decimal, and costs are nominal. Long-term figures come from a Minnesota study, not Pennsylvania. Query responses were checked against the published values directly; PDF sources were checked by extracting their text; the EPA guide, which blocks automated access, was read manually; one vendor figure with no traceable source is labelled as such. Two research steps ran in reduced form: this site’s own page inventory was read from its sitemap and five key pages rather than crawled, because the host blocks automated requests, and the comparison of which content formats earn links in this niche used three named radon sites after automatic competitor discovery returned only vendor link profiles.

  • Sources consulted: 31
  • Sources cited: 17
  • Data freshness: current year: 11, last year: 2, older: 4
  • Data range: 1988-01-01 to 2026-10-24
  • Research date: 2026-10-24
  • Update schedule: Annually, after DEP's first-quarter register refresh
  • Limitations: Post-mitigation results are short-term tests reported to DEP by certified contractors shortly after installation; the register cannot show call-backs, later failures or untested homes. Matching pairs a pre-test with a post-test at the same location and floor using DEP's test result identifiers. Percentages are truncated, not rounded, to one decimal. Long-term figures come from Minnesota, not Pennsylvania.

Using this data: You are welcome to use these figures or charts in your own article, report or presentation, with a link back to this page as the source.

Frequently Asked Questions

How much does radon mitigation lower radon levels in York County?

In PA DEP's register, 9,063 mitigated York and Adams County homes went from a median of 12.5 pCi/L before to 1 pCi/L after, a median drop of 92%. 98.2% tested under the 4.0 action level on the post-mitigation test, and 77% tested under 2.0. Results come from contractor-reported short-term tests taken shortly after installation. (PA DEP mitigation register, 2026)

Does a very high radon reading mean mitigation will work less well?

No. In the York and Adams data, homes that started at 50 pCi/L or higher (median 79) ended at a median of 0.9 pCi/L after mitigation, the same as homes that started between 4 and 8. Higher starting homes still landed under 4.0 95.7% of the time. The percentage drop is bigger because the starting number is bigger. (PA DEP mitigation register, 2026)

How often does a radon system fail its first test?

Rarely in the state data. 159 of 9,063 York and Adams homes, fewer than 2 in 100, had a recorded post-mitigation test at or above 4.0 pCi/L, and 4,683 of 170,077 statewide. Vendor guides often claim 5 to 15 percent of installs miss on the first try, but cite no source. The register records what certified contractors report and cannot show call-backs. (PA DEP mitigation register, 2026)

Do radon systems keep working years later?

Pennsylvania does not track it: DEP's test-results register does not record whether a tested home has a system. The best long-term evidence comes from Minnesota, where a peer-reviewed study of 140 randomly selected mitigated homes found about 97% still under the action level years after installation. An earlier report from the same project put the average system age at 2.3 years. DEP recommends retesting every two years. (Steck, Health Physics 103(3), 2012; Steck, AARST Symposium 2008)

What does radon mitigation cost in York County now?

The median system cost recorded in PA DEP's register for York and Adams County installs was $1,232 in 2025, up from $875 in 2015. Activating a builder's passive pipe recorded a median of $650 across all years. DEP's January 2026 guidance still puts most systems at $800 to $1,200, so recent local jobs sit at or slightly above that range. (PA DEP mitigation register, 2025)

Is sealing cracks enough to fix radon?

Not usually. Only 13 York and Adams homes in the register were treated with sealing alone; their median post-mitigation reading was 3.5 pCi/L and just 61.5% tested under 4.0, against 98.1% for standard sub-slab systems across 7,149 homes. The sealing sample is small, but the gap matches EPA guidance that sealing works best as part of a suction system. (PA DEP mitigation register, 2026)

What if radon is still high after mitigation?

It happens, but rarely. 159 of 9,063 York and Adams homes in PA DEP’s register, fewer than 2 in 100, had a follow-up test at or above 4.0 pCi/L. The first call is back to the installer, who can check the fan and suction and may add a suction point, change the fan, or seal a sump or large opening. Check that the fan is running and the manometer shows suction, then retest. Our guide to what happens after a failed radon test covers the next steps.

Is radon mitigation a hoax?

No. The results are measured, not claimed. Of 9,063 York and Adams County homes in PA DEP’s register that started at 4.0 pCi/L or higher, 98.2% tested under 4.0 after a system went in, and the median reading fell from 12.5 to 1 pCi/L. Those follow-up tests are reported by the contractors, so it is reasonable to run your own independent test afterward, which the EPA recommends anyway. For why radon matters, see the EPA’s radon page.

Sources & References

  1. PA DEP mitigation register. “Matched before/after results, York and Adams counties.” data.pa.gov/resource/vm4e-6nir.json?%24query=SELECT+count%28%2A%29+AS+homes%2C+m. Accessed 2026-10-24.
  2. PA DEP mitigation register. “Matched before/after results by county.” data.pa.gov/resource/vm4e-6nir.json?%24query=SELECT+mitigationcounty%2C+count%28. Accessed 2026-10-24.
  3. PA DEP mitigation register. “Matched before/after results, all Pennsylvania.” data.pa.gov/resource/vm4e-6nir.json?%24query=SELECT+count%28%2A%29+AS+homes%2C+m. Accessed 2026-10-24.
  4. PA DEP mitigation register. “Results by starting radon level, York and Adams.” data.pa.gov/resource/vm4e-6nir.json?%24query=SELECT+case%28measurevalue%3A%3Anum. Accessed 2026-10-24.
  5. PA DEP mitigation register. “Results by system type, York and Adams.” data.pa.gov/resource/vm4e-6nir.json?%24query=SELECT+remediationsystemdesc%2C+cou. Accessed 2026-10-24.
  6. PA DEP mitigation register. “Results by ZIP code, York and Adams.” data.pa.gov/resource/vm4e-6nir.json?%24query=SELECT+substring%28addresspostalcod. Accessed 2026-10-24.
  7. PA DEP mitigation register. “Systems and median cost by year, York and Adams.” data.pa.gov/resource/vm4e-6nir.json?%24query=SELECT+mitiyear%2C+count%28%2A%29+A. Accessed 2026-10-24.
  8. PA DEP mitigation register. “Register records by county.” data.pa.gov/resource/vm4e-6nir.json?%24query=SELECT+mitigationcounty%2C+count%28. Accessed 2026-10-24.
  9. PA DEP Radon Test Results register (data.pa.gov). “Mitigation-system field, York and Adams test records.” data.pa.gov/resource/vkjb-sx3k.json?%24query=SELECT+county_name%2C+mitigation_sy. Accessed 2026-10-24.
  10. Steck, Health Physics 103(3), 2012. “The effectiveness of mitigation for reducing radon risk in single-family Minnesota homes.” digitalcommons.csbsju.edu/physics_pubs/1. Accessed 2026-10-24.
  11. Steck, AARST Symposium 2008. “Post Mitigation Radon Concentrations in Minnesota Homes.” employees.csbsju.edu/dsteck/mnradon/16-POST-MITIGATION_RADON_CONCENTRATIONS_IN_M. Accessed 2026-10-24.
  12. PA DEP Radon Division stakeholder update, Sept 2025. “PA Radon Division update, subsequent post-mitigation testing.” sosradon.org/sites/sosradon/files/Stakeholders_Meetings/PA%20STAKEHOLDER_MTG-DIV. Accessed 2026-10-24.
  13. PA DEP Bureau of Radiation Protection. “Exploratory Study of ASD Ground-Level Exhaust on Radon Re-entrainment.” sosradon.org/sites/sosradon/files/Stakeholders_Meetings/Radon%20Re-entrainment%2. Accessed 2026-10-24.
  14. Brodhead, Measuring At-Grade Radon Mitigation Exhaust (AARST 2020). “Measuring At-Grade Radon Mitigation Exhaust.” wpb-radon.com/Radon_research_papers/2020%20Virtual%20Conference/Measuring%20at%2. Accessed 2026-10-24.
  15. US EPA, Consumer's Guide to Radon Reduction. “A Consumer's Guide to Radon Reduction: How to Fix Your Home.” epa.gov/sites/production/files/2016-02/documents/2013_consumers_guide_to_radon_r. Accessed 2026-10-24.
  16. PA DEP Radon Action Month release, Jan 2026. “DEP Encourages Pennsylvanians to Test Their Homes for Radon.” pa.gov/agencies/dep/newsroom/2026-01-12-dep-encourages-pennsylvanians-to-test-th. Accessed 2026-10-24.
  17. inspectandtest.net (vendor guide). “Radon elimination system guide.” inspectandtest.net/guides/radon-elimination-system/. Accessed 2026-10-24.